| Título: | CCQM-K170 - Electrolytic Conductivity at 0.5 S m-1 and 20 S m-1. Final Report |
| Autores: | HAI WANG, Autor ; MEILING WANG, Autor ; XIAOPING SONG, Autor ; STEPHEN SEITZ, Autor ; MICHAL MÁRIÁSSY, Autor ; DANIEL NAGY, Autor ; JORGE URIBE GODÍNEZ, Autor ; JOSÉ LUIS ORTIZ APARICIO, Autor ; MARTINA VIČAROVÁ, Autor ; JAVIER VÁSQUEZ ARELLÁN, Autor ; JIMENA PATRICIA TORREZ QUISPE, Autor ; JAVIER VÁSQUEZ ARELLÁN, Autor ; CHRISTIAN URIBE, Autor ; HENRY TORRES QUESADA, Autor ; GINA TORRES, Autor ; BRIGETTE SUAZA, Autor ; FABIANO BARBIERI GONZAGA, Autor ; KLEITON DA CRUZ CUNHA, Autor ; ARIEL GALLI, Autor ; MABEL PUELLES, Autor ; ÁNGELES RINALDI, Autor ; MAULIMGAZINOVA SHARBANU, Autor ; FAJARDO, SIMONE, Autor ; MARÍA VICTORIA GELABERT, Autor ; YUYA HIBINO, Autor ; NONGLUCK TANGPAISARNKUL, Autor ; EMRAH YILDIRIM, Autor ; CONNY HARALDSSON, Autor ; ZUZANA HANKOVÁ, Autor ; ZUZANA KODADOVÁ, Autor ; EMRAH UYSAL, Autor ; LOKMAN LIV, Autor ; SERAP GENÇTÜRK TOSUN, Autor ; TATYANA E. ALIMOVA, Autor ; SERGEY V. PROKUNIN, Autor ; RO YURIY A OVCHINNIKOV, Autor ; VLADIMIR DOBROVOLSKIY, Autor ; BEDNOVA MARIA, Autor ; STRELNIKOV ALEKSANDR, Autor |
| Tipo de documento: | documento electrónico |
| Fecha de publicación: | 2024 |
| ISBN/ISSN/DL: | 69815 |
| Dimensiones: | 25 p. / tablas, gráficos |
| Nota general: | En: Metrologia, 62, 08002. DOI: https://doi.org/10.1088/0026-1394/62/1A/08002 |
| Langues: | Inglés |
| Clasificación: | |
| Resumen: | The comparison CCQM-K170 is a subsequent key comparison of CCQM-K36.2016 and CCQM-K92. It aims to demonstrate the capabilities of the participating NMIs/DIs to measure the electrolytic conductivity of aqueous electrolyte solution in the electrolytic conductivity range around 0.5 S m-1 and 20 S m-1. The coordinating institute (NIM) prepared two potassium chloride solutions with the nominal electrolytic conductivity of 0.5 S m-1 and 20 S m-1, and verified their homogeneity and stability. Seventeen and twelve NMIs/DIs, respectively, reported their measurement results of 0.5 S m-1 and 20 S m-1 samples, respectively. The institutes used primary and secondary methods, and commercial instruments. Institutes using non-NMI CRMs as calibrants or CRMs from a participating NMI were excluded from KCRV calculation. The measurement results traceable to CRMs from the same non-participating NMI were combined into one result to be used for KCRV calculation. The results of institutes which have indicated technical problems were also excluded from KCRV calculation. The medians were agreed upon as the KCRVs for 0.5 S m-1 and 20 S m-1 solutions based on CCQM/2013-22 guidance document. Good agreement of the results was observed for the majority of participants. The results of this key comparison are considered representative for electrolytic conductivity measurement of aqueous electrolyte solution in the electrolytic conductivity range 0.15 S m-1 to 1.5 S m-1 and 5 S m-1 to 25 S m-1, respectively. This KC is intended as an updated support for the corresponding calibration and measurement capabilities (CMCs) entries in the key comparison data base of the BIPM. |
| Creative Commons : | CC BY |
| En línea: | https://iopscience.iop.org/article/10.1088/0026-1394/62/1A/08002 |
Documentos electrónicos (1)
Descargar documento - 32974 Adobe Acrobat PDF |